Free Engineering Tool
Enter your material, capacity and line length to see the required pipe diameter, air flow, pressure drop and blower motor power in seconds – together with a 3D simulation of your line.
Blower Guide
A blower is a machine that delivers a continuous, high volume of air at medium pressure. Fans move large volumes at low pressure, compressors deliver less air at high pressure; a blower sits in between, which makes it the ideal air source for conveying material through pipes.
In the plastics industry blowers drive pneumatic conveying lines that move granules and powders from silos to machines, or from tankers and big bags to silos. They are also used for wastewater aeration, vacuum loading, drying and air knives.
See the Botex machine built for silo filling and line feeding: Blower Machine – Pneumatic Conveying.
An impeller repeatedly accelerates air along a side channel in the housing to build pressure. Compact, oil-free and low-maintenance. Economical for short lines, low-to-medium pressure and low flow.
Two lobed rotors turn without touching and carry a fixed volume of air from inlet to outlet on every turn (positive displacement). Flow drops very little as pressure rises, so it is preferred for long lines and higher pressure.
The same blower connected on the suction side runs the line under vacuum: it pulls air from a filter receiver at the end of the line and material is sucked into the receiver. Ideal for collecting from several points and dust-free operation; practical limit is about 450 mbar vacuum.
When the line is very long or the material heavy, pressure loss exceeds dilute-phase limits. Then a high-pressure Roots blower or compressor-driven dense-phase conveying is considered; material moves slowly and without breakage.
Our calculator recommends a side channel blower below about 250 mbar and 1000 m³/h, a Roots blower above that, and warns for dense phase above 900 mbar.
The calculator above does all these steps; blower calculator. For the whole system see Pneumatic Conveying Systems.
Air flow is the air velocity in the pipe multiplied by the pipe cross-section:
A (m²) = π × d² / 4
Q (m³/h) = v (m/s) × A (m²) × 3600
v (m/s) = Q (m³/h) / (A × 3600)
Example: for a Ø65 mm pipe at 20 m/s, the cross-section is 3.14 × 0.065² / 4 = 0.00332 m². Air flow is 20 × 0.00332 × 3600 ≈ 239 m³/h. Conversely, if you know the flow you can find the velocity with the same formula.
Line velocity depends on the material: about 20 m/s for plastic granules, 18 m/s for powders, 22–25 m/s for heavy materials. Too low and material settles and blocks the pipe; too high and granules break, create fines and streamers, and wear the bends.
P (kW) = Q (m³/s) × Δp (Pa) / (1000 × η)
Q is air flow, Δp total pressure drop, η blower efficiency (about 0.45 for side channel, 0.60 for Roots). Example: for 239 m³/h (0.0664 m³/s) and 200 mbar (20,000 Pa) with a side channel blower, shaft power is 0.0664 × 20,000 / (1000 × 0.45) ≈ 2.95 kW. Adding 10% margin, the next standard motor is 4 kW.
Total pressure drop is the sum of air friction, material friction, acceleration at the feed point and bends, vertical lift and filter/cyclone/rotary valve losses. The calculator shows each separately and adds a 20% safety margin.
Calculator results for PE/PP granules, pressure system, 20 m horizontal + 6 m vertical line and 3 bends:
| Capacity | Pipe | Air flow | Pressure | Motor | Blower type |
|---|---|---|---|---|---|
| 300 kg/h | Ø40 mm | 90 m³/h | 259 mbar | 1.5 kW | Roots |
| 500 kg/h | Ø40 mm | 90 m³/h | 343 mbar | 2.2 kW | Roots |
| 1,000 kg/h | Ø50 mm | 141 m³/h | 345 mbar | 3 kW | Roots |
| 2,000 kg/h | Ø65 mm | 239 m³/h | 327 mbar | 4 kW | Roots |
| 3,000 kg/h | Ø80 mm | 362 m³/h | 288 mbar | 5.5 kW | Roots |
| 5,000 kg/h | Ø100 mm | 565 m³/h | 267 mbar | 11 kW | Roots |
Preliminary estimate; material, routing and altitude change the result. Use the tool above for your own line.
You can also calculate how many tonnes your silo holds with the Silo Calculator. To distribute raw material to several machines from one point, see Central Feeding Systems.
The right blower is the one that fits your line, not the biggest one: an oversized blower wastes energy and breaks granules, an undersized one causes blockages. Send your result via WhatsApp or request a free site survey for a project-specific price.
First the line velocity and air-to-material ratio needed to convey the material are set. This gives the air flow (m³/h) and pipe diameter. Then horizontal and vertical length, bends, material friction and acceleration, and filter/cyclone losses are added to get the total pressure drop (mbar). Flow and pressure give the motor power.
In general side channel blowers suit short lines below 250 mbar and 1000 m³/h. Longer lines and higher pressures need Roots blowers. Above 900 mbar, dense-phase conveying should be considered.
No, it is a preliminary estimate. Moisture, particle size, temperature, real routing and altitude change the result. We confirm the selection with a free on-site survey.
A blower delivers air at medium pressure and high flow. A fan moves a lot of air at low pressure, not enough to convey material through a pipe. A compressor makes high pressure but less air for the same energy. That is why blowers are used for pneumatic conveying.
A Roots blower is a positive-displacement blower whose two lobed rotors turn without touching and push a fixed volume of air every turn. Because flow drops little as pressure rises, it is preferred for long conveying lines and higher pressure.
A vacuum blower draws air from a filter receiver at the end of the line. The vacuum pulls material from the pick-up point into the receiver, the filter holds the dust and clean air leaves through the blower. The practical limit is about 450 mbar vacuum.
The pipe cross-section comes from the required air flow and the right line velocity for the material, then is rounded up to a standard size (Ø40, 50, 65, 80, 100, 125, 150 mm…). A larger diameter needs more air at the same velocity, and therefore more motor power.
Yes. Every 90° bend slows the material, which must accelerate again; in the calculation it adds roughly 6 m of equivalent line. Avoiding unnecessary bends and using long-radius bends reduces pressure loss and wear.
Free On-site Survey
Leave your details and our engineer will call you within 24 hours. The survey is free, no prepayment.
Monday–Friday 09:00–18:00